Flow rate measures the volume of fluid passing a cross-section per unit of time. The metric system centers on m³/s with everyday use of L/min and L/h; GPM (gallons per minute) is common on American pumps and showers, while CFM (cubic feet per minute) serves air compressors and HVAC. This tool converts 10 flow units against m³/s, grouped into metric and imperial/US units. Definitions such as 1 GPM (US) = 3.785411784 L/min and 1 CFM = 0.028316846592 m³/min are exact. Everything runs locally in your browser.
Real-time sync with scientific notation for extreme values
One-click copy, fully local calculation, nothing uploaded
Covers pumps, water filters, HVAC and medical infusion
Common Conversion Formulas
1 m³/s = 1000 L/s
1 m³/h = 1/3600 m³/s
1 L/min = 1/60 L/s
1 L/h = 1/3600000 m³/s
1 mL/s = 0.001 L/s
1 mL/min = 1/60000 L/s
1 GPM (US) = 3.785411784 L/min
1 GPM (UK) = 4.54609 L/min
1 CFM = 0.028316846592 m³/min
1 m³/h ≈ 4.403 GPM (US)
Common Reference Values
Household faucet: 6–12 L/min
Shower head: 8–15 L/min
Human resting cardiac output: about 5 L/min
Home water filter: 1–3 L/min
Aquarium pump: 300–2000 L/h
Yangtze River average flow: about 30000 m³/s
Small air compressor: typically 2–10 CFM
How to Use
1 Click the input field of any unit card
2 Type a value — every other unit updates instantly
3 Press the copy button to copy a result
FAQ
What is GPM?
GPM = gallons per minute, common on American pumps and shower products. 1 GPM (US) = 3.785 L/min ≈ 0.063 L/s; the imperial (UK) GPM is slightly larger (4.546 L/min). Always check which gallon imported equipment uses.
What is CFM?
CFM = cubic feet per minute, standard for air compressors, vacuums and HVAC airflow. 1 CFM ≈ 1.699 m³/h ≈ 28.3 L/min. Small compressors typically deliver 2–10 CFM.
How do L/min and m³/h convert?
1 m³/h = 1000 L / 60 min ≈ 16.67 L/min; conversely 1 L/min = 0.06 m³/h. A 10 L/min shower equals about 0.6 m³/h.
Why is the real flow lower than the pump rating?
The rating is the maximum at a specific head. Actual flow decreases as piping resistance (head) grows, and is further reduced by pipe diameter, elbows and clogged filters; select pumps from the operating curve, not the headline number.
Flow rate vs flow velocity?
Flow rate is volume per unit time (m³/s); flow velocity is how fast the fluid moves (m/s). They are linked by Q = A × v: flow equals pipe cross-section times velocity.
What flow units do medical devices use?
Infusion pumps and ventilators use mL/min or mL/h: normal infusions run 1–10 mL/min, pumps adjust down to 0.1 mL/h; adult ventilator minute ventilation is about 5–8 L/min.